Advantages

  • Superior quality efficiency with two-stage execution of the compressor unit.
  • High quality IE3 electric motor, IE 4 optional.
  • Efficient motor cooling.
  • High ambient temperatures up to 45°C.
  • Delcos XL touch screen controller with improved supervision.
  • Closed cooling water circuit for compressor unit cooling.
  • Water-cooled models available.
  • Two high efficiency radial fans in accordance with the ErP efficiency standard of 2015.

Design

The design of the high-performance two-stage compression stage provides 100% oil-free, isothermal compression close to the isothermal, with high reliability due to constant low temperatures, allowing it to be used in demanding applications at ambient temperatures of up to 45°C. The design of the two-stage high-performance compression stage provides 100% oil-free, isothermal compression close to the isothermal, with high reliability due to constant low temperatures, allowing it to be used in demanding applications at ambient temperatures of up to 45°C.

Guaranteed efficiency is provided by the excellent IE3 electric motor, along with legal conformity, high reliability and operational safety – great benefits in addition to automated motor lubrication.

The compressors utilise two efficient radial fans in accordance with ErP Efficiency Legislation 2015, offering low noise levels, low pressure loss and excellent cooling performance. The closed water circuit for airend cooling achieves a constant low temperature level, also meaning that less gearboxes are required.

TECHNICAL SPECIFICATIONS

CompAir D – Technical SpecificationsD75 – D315

Fixed Speed

Model Refrigeration method Engine power

[kW]
Working pressure

[bar g]
Free air outlet 1]

[m3/min]
Dimensions
length x width x height

[mm]
Noise level2]

[dB(A)]
Weight

[kg]
8 bar g 10 bar g 8 bar g 10 bar g
D75 Air 75 8 – 10 12,91 10,63 2597 x 1744 x 2001 75 74 3023
Water 72 70 3223
D90 Air 90 8 – 10 15,65 13,79 2597 x 1744 x 2001 76 75 3223
Water 73 72 3423
D110 Air 110 8 – 10 19,51 17,39 2597 x 1744 x 2001 77 77 3265
Water 75 74 3465
D132 Air 132 8 – 10 22,39 20,50 2597 x 1744 x 2001 78 78 3432
Water 77 76 3632
D160 Air 160 10 22,33 2597 x 1744 x 2001 78 3644
Water 77 3844
D165 Water 160 8 – 10 29,1 24,9 3300 x 1994 x 2190 77 78 4715
D200 Water 200 8 – 10 36,1 32 3300 x 1994 x 2190 80 81 5060
D250 Water 250 8 – 10 44,5 37.2 3300 x 1994 x 2190 81 82 5215
D315 Water 315 8 – 10 49,2 44,5 3300 x 1994 x 2190 81 82 5520

D110RS – D315RS Variable speed

Model Refrigeration method Engine power

[kW]
Working pressure

[bar g]
Free air outlet 1]

[m3/min]
Dimensions
length x width x height

[mm]
Noise level2]

[db(A)]
70% de carga
Weight

[kg]
Min. Max.
D110RS-8 Air 110 4 – 8 8,89 19,51 2597 x 1744 x 2001 76 3278
Water 72 3478
D110RS-10 Air 110 4 – 10 10,51 17,68 2597 x 1744 x 2001 76 3278
Water 71 3478
D132RS-8 Air 132 4 – 8 8,95 22,95 2597 x 1744 x 2001 77 3476
Water 73 3676
D132RS-10 Air 132 4 – 10 10,51 21,10 2597 x 1744 x 2001 77 3476
Water 72 3676
D160RS-10 Air 160 4 – 10 10,40 23,52 2597 x 1744 x 2001 77 3688
Water 73 3888
D200RS-8.5 Water 200 4 – 8,5 17,3 37,4 3300 x 1994 x 2190 77 5110
D200RS-10 Water 200 4 – 10 18 33,2 3300 x 1994 x 2190 79 5110
D250RS-8.5 Water 250 4 – 8,5 17,4 46,9 3300 x 1994 x 2190 78 5265
D250RS-10 Water 250 4 – 10 18,4 41,7 3300 x 1994 x 2190 79 5265
D315RS-8.5 Water 315 4 – 8,5 16,6 51,k1 3300 x 1994 x 2190 78 5570
D315RS-10 Water 315 4 – 10 18,3 48,5 3300 x 1994 x 2190 79 5570

1 Data measured and defined according to ISO1217, fourth edition, Annexes C and E, under the following conditions:
Air inlet pressure 1 bar A / 14.5 psi; Air inlet temperature 20 °C / 68 °F; Humidity 0% (dry)

2 Measurements under free field conditions according to ISO 2151, tolerance ± 3dB(A)

 